DCMUC1 Munich

AI-ready Data Center
Munich

Munich is the latest datacenter development initiated by Data Center Partners. Located in Unterschleißheim, less than 20km from the Center of Munich, the Capital City of Bayern, this future-ready datacenter aims at bringing additional compute power to the large enterprises of the Region, including AI, HPC, cloud and IT companies.

With strong industries such as automotive, finance, insurance, media, TV, IT, retail or aerospace, and global tech giants having their German Headquarters here in Bayern, one of the most dynamic Regions in Germany, there are growing needs in terms of compute power for AI, storage, cloud, research & development and machine learning. This is the why have decided to launch this ambitious datacenter project with an estimated 30MVA of power.

Unterschleißheim is a well-connected area offering access to national and international telco operators. It is also close to an existing datacenter hub.

Therefore, the site can be used as a primary location. It is also a perfect strategic location as back-up site or for DRP purposes (disaster recovery plan).

Main Features

  • Expected 30MVA power connection
  • 10.000m2 gross area
  • Estimated PUE 1.2
  • Planned 17W IT-load
  • Targeting Tier 3 and EN50600 Certifications
  • RFS Phase 1 planned Mid-2027

Location

  • Located in Unterschleißheim.
  • Less than 20km from Munich City Center
  • Easy to reach via train, road, airport
  • Close to an existing datacenter hub.

Power

  • est. 30MVA total power connection
  • est. 17MW IT load
  • ca.6000m2 IT space
  • estimated PUE of 1.2
  • redundant power supply from national grid
  • N+1

Planned Services

  • Flexible cage and suite options
  • Remote hands
  • 24/7 security
  • Staging room and storage areas
  • Office space, meeting rooms and kitchen
  • Customer parking + EV charging station

Security

  • 24/7 on site security team
  • Complete CCTV site coverage
  • Perimeter fence 3 m high
  • Full authentification and access control
  • Vehicle traps

Planned Sustainability Measures

  • Renewable power sources
  • Waste heat reuse concept in progress with the Municipality and industrial partners
  • PV photovoltaic on roof & facades • Green facades
  • Free cooling chillers concept N+1

Connectivity

  • Carrier neutral
  • Access to major Tier I and Tier II carriers
  • Partnering e.g. with Gasline, EU-Networks, Colt, DE-CIX etc.

Planned Norms & Certifications

  • Uptime Tier III acc. to Uptime Institute
  • EN 50600 VK3
  • ISO 27001 / BSI Grundschutz
  • LEED Platinum
  • Additional certifications in planning (ISAE 3402, SSAE, etc.)

Timing

Phase 1 expected Mid-2027
ca. 8MW IT Load

3D renderings

  • top left: rendering office space
  • top right: rendering lounge space
  • bottom left: rendering IT space (white space)
  • bottom left: rendering IT space (with rack simulation)